DC 12V Motor Mini Vacuum Pump 370 Micro Air Pump Booster Pump Medical Pump Negative Pressure Suction Pumping Booster With Inlet And Vent,2 PCS
Share Facebook Twitter Pinterest Email

DC 12V Motor Mini Vacuum Pump 370 Micro Air Pump Booster Pump Medical Pump Negative Pressure Suction Pumping Booster With Inlet And Vent,2 PCS

Brand: ‎DANXQ
Product Code: MM2022
Availability: Pre-Order, Inquiry Price
US$0.00
- +

About this product

*Rated voltage: DC 12V

*Packing Include: 2 x pump...(If you need a lot of this item, you can contact us before you pay.Well try our best give you a big discount.)

*Gasp time:<10s(less than 10 seconds to pressurize from 0 to -55Kpa with 12.0V in a 100CC tank)

*Noise:Less than 55dB(Put a sponge of 5cm under the pump and distance to noise meter from 30cm.and while pressurizing from 0 to -50Kpa to test noise value at 12.0V voltage(FIG1))

*Curren:<650mA(During pressurization from 0 to -55KPa at DC 12.0V voltage)

Description

Test condition:
The standard of environment test is the ambient temperature of 20 ? and relativehumidity of 65?RH?If no disputes occur?the test can be conducted under the blow circumstance:the ambient temperature of 5-45 ?and relative humidity of 30?80? RH?
Rated voltage:12.0V
Operating voltage:11.5-13.0V
Curren:?650mA(During pressurization from 0 to -55KPa at DC 12.0V voltage)
Gasp time:?10s(less than 10 seconds to pressurize from 0 to -55Kpa with 12.0V in a 100CC tank)
Noise?Less than 55dB(Put a sponge of 5cm under the pump and distance to noise meter from 30cm.and while pressurizing from 0 to -50Kpa to test noise value at 12.0V voltage?FIG1?)
Max.Vacuum pressure:?-55Kpa(Rated voltage)
Flow LPM:?4.5 LPM(Rated voltage)
Low-temperature characteristic:Putting the pump in the temperature at negative 20? for 72 hours;then taking it out and putting it in a room temperature at 20?±5? for two hours.Under this circumstance ?running through test 3.3 3.4 3.5 3.6 3.7 3.8 3.9 and finding out that the pump still performs well.
High-temperature characteristic:
Putting the pump in the temperature at 60? for 72 hours;then taking it out and putting it in a room temperature at 20?±5? for two hours?Under this circumstance?running through test 3.3 3.4 3.5 3.6 3.7 3.8 3.9 and finding out that the pump still performs well.
Life test:
In a 100CC tank?pressurizing for 10seconds?stopping for 2 seconds?and deflating for 5 seconds is as one cycle?Doing it for 50?000 times?then examine the pump by test 3.3 3.4 3.5 3.6 3.7 3.8 3.9 and figure out that the pump is still in a good function.
Unusual test:
There is no burning and smoking occurrence while the power is on with DC 12.0V for 8 hours continuously